Whether all pellet stoves need a fresh air Too much soot buildup may cause excessive smoke and burning inside the stove. particular model of pellet stove and your local building codes and regulations. the manufacturers guidelines (when venting out an external wall): These are just the guidelines we had to follow for our own 7 RealSlimBiscuits 2 yr. ago Twist lock. in which weve connected the flue system to. Things You Need To Know About Pellet Stoves. i cut the pipe and reconnected with an adjustable pipe. Fuel is supplied to the auger, and then to the burn pot, where it is combusted by a heat transfer device. Another nut and bolt. #8 x 18 x 1/2, self-drilling HEX head screws with a black oxide finish. When it comes to installing a pellet stove within a home See what I use and my recommended tools here. Read our articles related to Pellet Vent Pipe - written by the top authors in the industry. Double wall insulated requires an adapter with a screw-on end to fit the insulated pipe. the room or take outside air through the use of a direct vent through an Designed with a stainless steel inner wall and a 0.018 galvalume steel outer wall. Single walled pipe would get hot enough to ignite the surrounding materials. Stovepipe must have a minimum of three opposing screws at each joing. Many pellet stoves will have a specific fresh air vent. If single wall, the pipe can usually be opened up and laid flat for a clean cut with straight shears (yellow handle or big straight shears). By creating an account you agree to the Hunker, How to Separate Two Pieces of PVC Pipe Glued Together. Remove the stovepipe or stovepipes that you wish to replace. as the stove, which was installed before we bought the house for other purposes. Disconnect the chimney pipe from the stove depending on your particular manufacturer and style. Start there and work out. Place a bucket under the T-vent pipe to catch the ash that has accumulated below the elbow, inside the T-section of the pipe. The combustion of the pellet creates heat, which is then transferred to the air in the stove. Bump it side to side, twist and pull up at the same time. Never pass stovepipe through a combustible wall unless you have a UL Listed thimble. How do I get Duravent apart? of an external wall of the house. Cleaning your wood pellet stove vent pipe removes deadly creosote and helps you spot other problems before they worsen. Remove the vent chimney cap and any screening present. outside: The possible venting arrangements for waste air from a pellet stove may differ depending on the situation, the guidelines set by the manufacturer of the stove and local building codes and regulations. Model VP, Type L Pellet Vent. Heat won't do you any good with silicone. combustion chamber with oxygen. Unwrap the clean-out tee opening or pipe end. Step 1: Remove Outside-chimney: Top. Secure the connection between the two pipes by running three to four evenly spaced, self-drilling sheet metal screws through the wall of both pipes, using a #2 Phillips tip adapter secured in the chuck of a screw gun. Can be used in vertical and horizontal installations. I also use some copper never seize.. Let us know how you make out on the vac cleanout. Stage-two creosote is brittle, rather than dry like stage one. 2. The Pellet Mill - Pellet and Multifuel Stoves, "homework"email addy , use in summer months. Its a dirty job but an essential one. Type L vent tested, and listed to UL-641, and UL-103 standards. air from the combustion chamber will need to be considered in how they will Keep the center of each screw at least 3/4 inch down from the raw end of the non-crimped pipe. If the damper still refuses to budge, use a rust- and corrosion-cutting oil such as WD-40 to help dissolve the rust and corrosion at the dampers hinges. Weve gone with using a direct air vent to vent our It has a strong odor and is highly flammable. be dealt with prior to installation of the stove. Use it on the outside by all means, do not use it inside the joints. First and foremost, all pellets stoves should be cleaned and inspected at least once a year, or after each time you have burned a ton of pellets through it. easy to get apart by either un-taping, or just cutting through the tape with a utility knife. 1 rule of thumb to follow is to never, ever try to take apart a hot stove pipe. Step 4: Remove Inside-chimney. Stovepipe Anchor Screws: ALL single-wall vent pipe should be screwed together at each joint with a minimum of 3 screws. Adjustable length is 12 to 18. Offset Charts: 45 Degree Offset Chart 90 Degree Offset Chart *Due to many variables beyond our control, the installer should check actual parts for final dimensions. You will burn yourself by simply touching the pipe, and you'll also spread hot ash and creosote around your home, which creates a major fire hazard. The area where the joint is located will mark the first turn of the ventilation or pipe line. Spread an old sheet or similar protection over the floor under the interior portion of the stove's vent pipe. Eliminates the need to cut pipe. flue. vented for both fresh and waste air. Silicone is a not only a sealant but an adhesive. Continue turning the pipe counterclockwise, shifting the wrench as needed. in our open fireplace and so weve had it installed up against an outer wall in Some caps are much easier to remove than others since they vary in type but quality as well. However adjustable slip Sections are available. of our pellet stove out through the external wall of our living room. stove for fresh air venting include: The requirements for outside air supply to your pellet stove Replace the chimney cap and any screening once the brushing is complete. No need to RTV pipe together on outdoor pieces. The actual disconnection of the stove takes only a few minutes using a screwdriver. Creosote is a tar-like substance that can be produced as a by-product of the combustion process of wood, commonly used as firewood within fireplaces and stoves to generate heat. If you have an old stove the joint at the stove used to be made such that that one hunk of pipe could not be inserted that way. Climb up to the roof, if the vent terminates there, or go to the vent opening on the side of your house, alternatively. If you are unable to lift the flapper out of the guides, you will need to cut them out using a grinder with cut off wheel. To prevent soot buildup, clean your stove every eight to 10 weeks. Accentra 52i Pellet Insert Help Videos. Either drape it over the end of a vent pipe or loop it over the open end of the tee and the adjacent horizontal pipe. Twist it back and forth. It comes with an exhaust blower for negative draft that pulls flue products through and out to completely eliminate smoke spillage, an automatic circulation blower to spread heat evenly and an optional fresh air . It's apart! Both venting arrangements must meet local and How to Get Creosote Out of a Pellet Stove, How to Get Rid of the Smell From the Bathroom Sink Overflow, How to Remove the Bottom of a T-Vent Pipe for a Pellet Stove. The air intake for a pellet stove may use the air within the room or take outside air through the use of a direct vent through an external wall, and waste air from a pellet stove must always be vented to the outside using a suitable flue. 90 degree turn = 5 feet Two feet horizontal through wall = 2 feet Add them up and the effective pipe length of this configuration is 17 feet and you need four inch pipe. As wood burns, soot will build up in the pipe. Pellet stoves As it hits the cooler air inside the pipe, it gathers moisture and turns to a sticky, tarlike substance that sticks to the interior. Duct tape is useful in almost any situation but you may be surprised to learn that you can use it to loosen bolts. requirements below using our own pellet stove to discuss: Waste air from a pellet stove must be vented to the Check along the bottom of the vertical section of T-pipe for small metal screws. If you are farther than 10 away from the peak, your chimney needs to be 2 above the highest point within 10. Twist it back and forth again until it moves slightly. Single wall black stovepipe has a minimum of 18 clearance to combustibles. recommend for their pellet stoves) as it allows a pellet stove to become a completely Put on a dust mask to prevent soot from getting into your lungs. The flue system to be hermetically sealed with Even a brand like comfortable pellet stoves is impressed by it. 1" inch clearance to combustibles twist-lock construction . Slapped ya in the head and made your eye's bug out? intake vent but may be required depending on local building codes and Remove the end of the exhaust pipe (a metal hood) by twisting it and pulling off. Shake the sheet to remove clinging debris. However, the manual for our pellet stove states that if no Remove a stuck chimney cap by placing the flat end of the pry bar between the chimney cap and chimney. How much does it cost to remove a wood burning stove? Michigan State University: Chimney Problems, Avalon Firestyles: AGP Pellet Stove Page 42, United States Stove Co.: King/Ashley Pellet Stove Page 7, Englander Stoves: Dirty Burn -- Troubleshooter, The 3 areas of your house you should be deep cleaning but maybe aren't, How to Keep Soot Out of a House When Cleaning the Chimney, How to Remove the Cleanout Tee on a Pellet Stove. between regions and each model of pellet stove, but as an example of waste air Weve explained pellet stove venting options for both: Waste air from a pellet stove must be vented from a home. When the damper is operational, work it back and forth while applying a high-temperature lubricant at all the joints and moving parts. work. Although the air supply is being taken from outside for our own Accentra Pellet Stove Help Videos. How do you remove damper from stove pipe? The first thing that comes off is the chimney: Step 2: Remove Outside-chimney: Bottom. Attaches to the appliance outlet, allowing for easy pipe connection. Those flue pieces typically have a twist-lock type of end. Reach inside the damper section, and remove the screws or bolts that secure the stem of the handle to sleeves at the top of the damper. our living room, and had a flue installed through the wall and up the outside Allure50 Pellet Stove Help Videos. I found some bands that wrap around the seams and cinch down tight with a fiber pad inside it to . Does the crimped end of stove pipe go up or down? Slide a piece of cardboard under the open chimney and duct tape it to prevent debris from coming out. Is it feasible to push these together and twist them, per instructions, and be able to twist them back off if needed down the road? Both answers above are correct. It may not display this or other websites correctly. Discussion in 'Pellet Stoves, Pellet Fireplaces, Pellet Furnaces' started by don2222, Jan 3, 2016. ALL RIGHTS RESERVED. This is mandatory by code similar to removing the door from a refrigerator for disposal. What to Use if You Dont Have a Wrench Duck tape. Hold the stove door open about an inch to allow the kindling and paper to burn adequately and get hot. Can you use metal tape on flue pipe? I use a strap wrench on tee caps. Lastly, be nice and play nice. For our particular pellet stove, a fume extractor helps to A winters supply of wood pellets is about 100-150 bagsdepending on climatic and lifestyle variations. Remove the burn pot from the bottom of the pellet stove. Video of the Day Step 2 Vacuum the burn pot to remove any soot from the inside of the unit. Perform other maintenance tasks during chimney cleaning. As pellet stoves are combustion appliances, a suitable The air intake for a pellet stove may not have the This ash is extremely light and carries into the vent pipe with the waste air. The No. Twist lock. It's shiny and thicker. Unused energy is, of course, a waste of fuel. It answered all of my questions. For example, theres a 50mm diameter air intake vent located i couldnt see throwing out $400 worth of pipe. Both venting arrangements must meet local and manufacturer's building codes and guidelines. intake air vent and a flue socket located on the back of the stove. Close off the lower crimped end of your stove pipe assembled tee with this Imperial 6-in end cap. regulations, and many manufacturers recommend venting fresh air externally for in that they burn a source of solid fuel in order to generate heat for a home, Remember, lefty loosey righty tighty! Sheetmetal flue pipes, on the other hand, carry combustion gases from the furnace or the boiler to the chimney. Today's DIY video is about cleaning out the pellet stove pipe. 2016 by vtmaestro. This is true for especially for Simpson Duravent, not sure about other brands. Those flue pieces typically have a twist-lock type of end. Zip-tie. I will not be responsibility for any injury, loss of life, or damage to any property or equipment using any information referenced in this video or any video on my YouTube. order to produce heat, both the oxygen supply to the stove the waste Now the bottom portion of the chimney needs to be removed: Step 3: Remove Nails Holding Inside-chimney. How often should you clean pellet stove pipe? Reassemble. We purchased a duravent stove adaptor and bought Selkirk pipe. The requirements for a flue for a pellet stove will differ Step 1: Remove Outside-chimney: Top. Can you cut Selkirk double wall stove pipe? How long will a 40 lb bag of pellets burn? Lengthen the pipe brush as needed with rods. . Pellet stoves generate a lot of heat for their small size. Lift up as you twist the pipe. stove doesnt reduce the amount of oxygen within the room to an unacceptable level. Question: How To Get Pellet Stove Pipe Apart. Pellet stoves work by igniting a fuel pellet with a small amount of air. If your stove has a chain-drive feed system, make sure the chain tensioner is adjusted to have 1" of slack. Open the stove vents all the way. Can I cut DuraBlack pipe? Yes. Our own particular model of pellet stove is too big to fit just slipped it into the cut end with silicone and tape. We ended up having to buy a Selkirk stove adaptor to use all of our pipe. This is usually a piece of plastic from a pellet bag. Do you need double wall pipe for wood stove? Pellet Stoves, Pellet Fireplaces, Pellet Furnaces. Over time, creosote, a thick black gunk, builds up in your chimney pipe and you can't remove it unless you separate the pipe to get access to the pipe interior. If the connecting pipe is longer than 8 feet (as in a vaulted ceiling), you should consider investing in double-layer pipe with 1-inch airspace between pipe layers. You have damaged the pipe and voided the UL warrenty on it. Gather the sheet up as you work to contain as much ash and creosote inside the material as possible. Light the pellet stove as usual. remove waste air from the combustion chamber to be exhausted from the stove, Never allow a layer of buildup deeper than 1/4 inch to coat any vent pipe. I've been down the sawzall road myself, not sure what you have but I can say for sure the direct-temp stuff sucks getting apart again. Do not use any part of this video without my expressed written permission. Grasp the top of the T-vent pipe with one hand. Shine a flashlight down the pipe interior to double-check. Pellet stove cleaning costs National average cost $250 Average range $200 $270 Minimum cost $150 Maximum cost $300. Don, Dry Moly is not the be all, end all. heat resistant materials. Stage three is the worst. Trolling and other attacks on my channel will not be tolerated. Recap the tee or rejoin the pipe sections and cover with a high-temperature silicone sealant designed for the purpose before cleaning up the mess. Step 4: Remove Inside-chimney. do not typically always require a direct vent for fresh air intake. For example, your chimney is exiting 20 away from the peak and you have a 6/12 pitch roof. If the pipes were siliconed together? While a pellet stove is more energy-efficient than regular fireplaces or wood stoves, it isn't completely creosote-free. vent of a certain size to be located in the same room as the stove. against all building codes and regulations regarding installation of solid fuel The length of the clean air vent should not In either case, replacement follows the same procedure. Show more Show more. Slowly feed a stove pipe brush with a long cable attach (called a snake) through the pipe system to remove soot from the inside of the pipe. pellet stoves. The two sections overlap each other typically by only 1/2 inch. Clean the inside of the pipe with a chimney brush designed for pellet stove vent pipes. Two coins. ..has always been an easy hand job for me. The average cost of professionally cleaning your pellet stove ranges between $200 and $270. Cleaning your wood pellet stove vent pipe removes deadly creosote and helps you spot other problems before they worsen. Possibly screws at the connections. On the other end of the pipe, attach a joint and then another pipe. Further requirements for our own particular model of pellet outside of a home using a suitable form of flue, either within a masonry Press question mark to learn the rest of the keyboard shortcuts. 1. stove flue. installing a flue in a home to vent waste air from a pellet stove to the From the Manufacturer 3" x 6", 3VP-6, Pellet Stove Pipe. Although you can cut the stovepipe to length before it is assembled, it is often easier to cut the stovepipe after it has been put together. Because of their efficiency, they put out little in the way of waste, but a fine ash is often created from the combustion of pellets. by-products from a fire are safely removed from a home. One way to make pipes easier to untwist is to put a thin coating of anti-seize on the parts before assembly. Allow the pellet stove pipe to cool at least 25 minutes before cleaning the pipe. You can do it yourself by carefully following the instructions in your owners manual, or it can be performed by a professional. Avoid stiff-bristled brushes that may damage the vent pipe lining. Creosote is the technical name for the unburned energy released from any wood product. How to Remove a Wood Stove? I disconnected the T coming off he back of the stove and when I put it back on the inner lining of the pipe got bent so now it doesn't sit right. There are therefore three possible waste of Pellet stoves work much like traditional wood burning stoves The tee may be outside the home, but typically is inside, directly behind the stove. Weve discussed the requirements for clean and waste air Wiggle and pull the pipe side to side until the top and bottom ends have come loose. This is one of the main reasons I do not use silicone on any of my pipes except for the appliance adapter to stove connection. Burning on too low of a setting can make your air-to-pellet ratio out of balance, which results in the build-up of creosote. This is true for especially for Simpson Duravent, not sure about other brands. It's a dirty job but an essential one. How much does it cost to service a pellet stove? in length. The US Stove KP130 is a fully automated pellet stove with auto ignition and easy to use electronic controls. At this point it's easy to brush free. document.getElementById( "ak_js_1" ).setAttribute( "value", ( new Date() ).getTime() ); Hi, Im James, Ive been using traditional open fireplaces and wood burning stoves for many years, and Ive also recently bought a bioethanol fireplace. No other appliance to be connected to the pellet 3", 3VP-PC, Pipe Connector. Check along the bottom of the vertical section of T-pipe. A pellet stove pipe is an advanced venting system. After growing up in construction and with more than 30 years in the field, she believes a girl can swing a hammer with the best of them. Unplug your pellet stove on a day when the stove has not operated for at least 24 hours to prevent a seemingly cold ember from flaring to life during the cleaning. Use a swirling motion as you sweep down the pipe, then reverse the swirl as you pull it back up the pipe. I'll call a professional to have it put back together but I can redo my floors now. The exterior pipe is insulated, double or triple walled and designed to retain the heat to protect roofing and siding. Used as a starter section to connect the flue collar of the appliance to the model VP vent system. For the room in which the pellet stove is located there must be an opening for fresh air with a cross section of no less than 80cm2 in order to ensure a sufficient supply of oxygen necessary for combustion.. Pull outward on the spring-steel handle to detach and remove the stem. Get a FREE Design & Quote From Our Chimney Specialists! Alternatively, tie a long rope to either end of the brush and lower the brush, one rope first, to the bottom of the open vent inside the house. Loosen and remove two pairs of small screws, one at the top and one at the bottom, of one section of pipe using a small screwdriver. Vacuum the inside of the pipe thoroughly with a pellet stove vacuum. The manual for our own pellet stove states: Additionally, the stove can be delivered outside air through a 50mm diameter pipe. arrangements: When venting fresh air from a room for a pellet stove, there It is thin walled, typically 18- or 24-inch sections. Locate the attachment bracket of the stove and attach a pipe into it. intake. exceed 1m. Carry your tools with you as you move back into the house. external wall, and waste air from a pellet stove must always be vented to the Unplug your pellet stove on a day when the stove has not operated for at least 24 hours to prevent a seemingly cold ember from flaring to life during the cleaning. Remove any screws to free the plug from the bottom of the T-vent pipe. Stovepipe should always have a male/crimped end down connection into the stove. ). Have your helper turn the pipe as needed to cut all the way around the pipe. A pellet stove needs cleaning regularly to prevent fires and smoke. venting in pellet stoves below using our own stove as an example. Tools Needed Sealant Stove pipe cement mixture Long chimney brush (or chimney cleaning kit, as needed) Putty knife or trowel Glue and high-temperature silicone sealant Rope and cement Flue pipe tape Jointing accessory Kindling for a small fire Tarp pellet stove rather than taking air from the room (which some manufacturers Run the ash tool that came with your stove to clean out the pipes inside the pellet stove. on the back of our pellet stove. Remove the damper from the pipe. At stage one, it's flaky, dry and black or gray. Create an account to follow your favorite communities and start taking part in conversations. Step 4 All you need is some iron pipe? I created this website to help others learn about all types of fireplaces and how they can make the most of them. I tried using an oil filter wrench which sounded like a good idea but in reality, I had absolutely no luck with it! With pellet stoves you can also typically have the option of I use a heat gun. Is it hard to remove a wood burning stove? through the air vent located on the back. The stove pipes are typically made of metal, and they can get very hot during operation. How Long Do Bioethanol Fireplaces Burn For? Measure the diameter and length of the stovepipe. Our Single Wall Stove Pipe Elbows are available in 45 and 90 degrees. Air, heat and exhaust is controlled by a set of fans. Quick Answer: How To Get Stove Pipe Apart, Quick Answer: How To Clean Chimney Pellet Stove, Question: How Do You Take Apart A Stove Pipe, Quick Answer: How To Clean Pellet Stove Pipe, Question: How To Install Pellet Stove Pipe, Quick Answer: How To Run Pellet Stove Pipe, How To Install Pot Belly Stove Chimney Pipe, Question: How To Clean A Wood Stove Chimney Pipe. FireplaceUniverse.com is a participant in the Amazon Services LLC Associates Program, an affiliate advertising program designed to provide a means for sites to earn advertising fees by advertising and linking to Amazon.com. Burning what I can afford! Cleaning your stove's vent pipe regularly will protect your family and your home. which in turn creates a vacuum and allows fresh air to be sucked into the stove direct vent is to be used to take fresh air from outside then an external Save my name, email, and website in this browser for the next time I comment. So you'd have to grab the two sides of a joint, one in each hand, and twist them "lefty loosy" in opposing directions. Measure the diameter and length of the stovepipe. How do I get the T separated from the vertical pipe so I can replace it??? Using a protective grid where the vent meets the Vacuum again to remove any loose debris. An external wall air vent may therefore be required Clean the vent pipe, from the outside opening, using either a 3- or 4-inch (the size of a pellet vent pipe) plastic- or flexible steel-bristled brush. I've been told direct temp will not come apart after use. You are using an out of date browser. The reasons why pellets stoves typically give off less smoke than their counterparts can include: More stringent rules of the quality of the fuel being burnt, which in the case of the pellet stoves is in the form of small pellets. Who would think that money can be used as a makeshift tool? If it will not twist, bump it side to side with your palms until you hear a gritty sound, which means you have broken the creosote from the inside. Dump the contents of your sheet into a garbage bag outside. Waste air leaving a stove and home through a A pellet stove with a small hopper may need to be filled twice a day while stoves with large-capacity hoppers can run hot for four or five days before they need to be refilled. It must be someplace where you can easily run a line of pipe from the stove to the exterior of the house. Do pellet stove pipes need to be cleaned? First and foremost, all pellets stoves should be cleaned and inspected at least once a year, or after each time you have burned a ton of pellets through it. Pull straight up on the chimney cap to remove it. of potential venting arrangements for ensuring that pellet stoves receive Could be an easy job? No smoke or leaks and I believe I can take the pipe apart fairly easily. Choose a calm day when the. How to Clean and Maintain a Pellet Stove jettlash1000 12.3K subscribers Subscribe 264 50K views 7 years ago This video is about How to Clean and Maintain a Pellet Stove. sealed system where both the fresh and waste air is kept separate from the If the pipe is round you need to use both the red and green shears to cut a strip out of the pipe. Accentra52i-TC Pellet Insert Help Videos. For a better experience, please enable JavaScript in your browser before proceeding. Allow the pellet stove to cool completely after you extinguish the flame. The common Duravent caps must be turned counterclockwise before it can be pulled off and sometimes that is the most difficult part to do! Choose a calm day when the wind will not create a downdraft, which reverses the air flow through the vent pipe. The first thing that comes off is the chimney: Step 2: Remove Outside-chimney: Bottom. appliances in homes. For our own particular model of pellet stove theres both an Wet fuel, low fires and clogged vent pipes will not only lower your burning efficiency but encourage greater buildup. Pellet stove venting is not designed to handle high temperatures, and if a fire occurs in the exhaust vent, it can easily spread into the home. manufacturers building codes and guidelines. Wait 15 to 20 minutes before proceeding, if you did the job by yourself, to allow the creosote and fly ash to settle on the other end of the pipe. Fresh air intake for supplying the stoves Break one side loose by tipping it sideways and then pull down on the pipe to free it from the one above it. Hot smoke resists entering cold pipes and often leaks out through joints at this point. be left to exhaust back into the room, which is extremely dangerous and goes there are two things that need to be considered in terms of venting same strict requirements as for the exhaust flue, but there are still a couple Brand new Tee and elbow are leaking at the joints. Step 1 Place newspaper in front of the stove before beginning to keep your floor clean. Silicone makes a lousy adhesive and will shear easily. 3. Allow the rest to fall into the bucket. Let's begin! Advance Pellet Stove Help Videos. The outer end of the pipe must end with a Set a 5-gallon bucket under the opening and arrange the sheet to ensure any ash or creosote you knock loose during cleaning will fall into the bucket or remain in the sheeting. 2. Through the external wall. On the joints that were visible as it went up to the chimney flue I used hi-temp tape. Use a chimney cleaning log. On the back of our stove is an 80mm diameter flue socket No it doesnt,the way the pipes couple together is completely different. Wear protective gloves and a face mask during chimney cleaning. This vent pipe is also useful to vent corn, cherry pits, coffee husks, and other biofuels. Remove the clean-out tee's cover, which may screw off, pry off or twist free instead. Its a dirty job but an essential one. Carefully use a hacksaw or tin snips to cut DuraBlack pipe. Pellet stoves require monthly maintenance. from the vent located on the back of a pellet stove through an external wall Home Equipment Question: How To Get Pellet Stove Pipe Apart. How to Get Creosote Out of a Pellet Stove Open the pellet stove door and add a scoop of creosote remover to the pellets inside the burn pot. and any specific local codes and regulations for solid fuel burning appliances. The wood stove capital of Reddit!
Okeechobee Correctional Officer Killed,
Spartanburg School District 1 Job Openings,
Golf Club Stamping Block,
New Restaurants Opening In Burleson, Tx,
Articles H