or if i let it rest for like 10 to 15 min it will start right up on its own when i hit the switch. If that all checks out, be sure that there are no air leaks on the suction side of the impeller, around the lid, drain plugs or pipe coming into pump. Does this seem odd or excessive? The only thing I can think of now is a bad breaker box which is outside adjacent to the pump, it is 20 years old. If so, it will always read 100%. After cleaning the pool the pool pump would just hum and not start. Improper voltage wiring is the usual culprit for smoking pump motors. Lubricating the lid o-ring regularly will help improve the seal. Does that have to be over the two spades or one? Find these plugs and remove them by loosening the wingnut and wiggling it out. Check that the timer clock motor is working. Products, learn If recalibrating your salt level did not resolve your problem, then your cell or your PCBoard is bad and needs replacing. I turned it on and it ran fine for about one hour. None of the indicating lights are on. heres the motor: https://www.intheswim.com/p/hayward-super-pump-pool-pump-motor-1-5-hp-threaded-shaft and the seal: https://www.intheswim.com/p/hayward-super-pump-shaft-seal-assembly-spx1600z2. gives you instant access to PDF files. Thanks, Steve DeGray. When the pump comes on a massive amount of bubbles comes out of the return line in the bottom of the pool. I was wondering, I have four returns coming into one pipe to the pump basket. I was just wondering if you thought that could be the issue unless it could be something else. Could be a loose lid, or the basket not re-placed properly, and a clogged pump impeller. Write Review Hayward AquaTrol HP Main PCB | GLX-PCB-TROL-HP $375.97 Quantity $17.35 / Month * Platinum Preferred Manufacturer Proposition 65 Warning hayward super pump C48L2N134B1. I owe you a beer if you are ever around my neck of the woods. You can also call Hayward directly for tech support. If you have trouble getting past this, an electrician may be a good call to make. The selector plug MUST be moved or the breaker will trip every time you try to start it up. the pump is working but not priming. You find these in our valve parts department or use one of our multiport valve rebuild kits. Humming Motor: If the pump motor makes a humming sound when starting up, you likely have a clogged impeller. Hayward Blue Essence Troubleshooting, Pool Supplies Near Me Open Now, Breville Tamper Coffee Kit 54mm, Used Cozzia Massage Chair, Power Pole Distribution Block, Signature Custom Cabinetry, hayward blue essence troubleshootinghi-c orange lavaburst bottle hayward blue essence troubleshooting Destacado beach outfit ideas for chubby The AquaTrol Are T-Cells interchangeable on Hayward AquaRite Systems? If no, test power on the wires coming into the pump, place test meter leads on the red and black wires, with power turned on to the pump. "@context": "https://schema.org/",
It is still running the same way, surging. If there is input power, the fuse may have blown. Could be one of these. Is there any other switch? If youre correct that theres a problem with the internal bypass, what should I do? Tried recalibration and no change. . When, Swimming pool pumps that are noisy can keep you from enjoying peaceful naps by the pool, or can keep your neighbors up, In-Floor pool cleaners have been around since the 70's when they became the answer to the complaints about traditional pool cleaners. Also use a rag to clean the surfaces that mate on the pump body. Hi Davy, Perflex filters can also leak out of the bump handle, this fix usually involves replacing the shaft o-rings. Are I on the right track? Hello we have a Hyward Power Flo Matrix 1 HP pump for a 15 foot above ground pool the pump runs however only seems to fill the strainer basket half way and is very noisy (like its struggling to get enough water in) the pressure guage on sand filter reads 15 psi and everything has been cleaned and new o-rings installed all around. Since you didnt say it trips a breaker, its probably not a short or ground-out of power, although it still could be, typically a wire touching metal other than the terminals on both end of the wire. Hi LInda, humming or buzzing, and not starting could be a few things first check that the shaft is spinning, either by spinning on the impeller end, or at the rear of the motor (power Off in both cases), to be sure the shaft is not bound up or seized. (returns are the lines going back to the pool, returning) Some pools can operate successfully with fewer than the original pipes, I have worked on many pools with abandoned main drains or skimmers that stopped working. I took the lid of the pump basket and cleaned the seal and placed it back on tightly, but there are small bubbles still coming out of the pool jets. Please help. Look for any small drips or oozing around the filter, or you may be able to hear a small hiss, when the pump shuts off. Question my Aquaririte is 3 years old. it will not pull up off the pump basket. If you remove the motor from the pump, and then turn on the power very briefly if the noise continues, its the bearings, if it runs quiet (high speed), then look to vibration or cavitation. Ive tried the override, checked the basket on the pump and felt into the intake and outlet for obstructions. I have a new fiberglass pool and ever since I operate it the pump trips the breaker in most cases overnight hours between 2 timing sessions (pump not running). Full membership to the IDM is for researchers who are fully committed to conducting their research in the IDM, preferably accommodated in the IDM complex, for 5 We would like to show you a description here but the site wont allow us. Any suggestions? Any insight? APPLY FILTER Pumps Filters Heaters Cleaners Sanitization Automation Lighting White Goods Accessories Solar Safety Please note: The majority of our literature and brochures are in English only. The pump shuts off because it trips the circuit breaker in the house. This time around I purchased the t-3 cell model since my pool is below 15k gallons. Hmmm, thats interestng, but I dont think you have a pump problem. My Hayward h250 propane heater keeps blowing fc1 and fc2 fuses immediately after plugging in. Is this a ground issue or something else? When I try to turn the pump back on, it only hums. Hi probably not related to the vacuuming, but sounds like a motor problem. Turned it off and now it makes the grinding noise and turns off itself. After trying every chemical under the sun and replacing the sand, I pulled the trigger and started from scratch. I checked the breakers, plumbing, control panel, plumbingjust need to know if I shud prepare myself to buy a replacement. Everything coming in appears to be tight. Also check that the stationary switch (6 oclock) and the centrifugal switch (dead center) are not loose or misaligned. For slide valves (aka push-pull valves), an o-ring on the bottom plunger disk has gone missing or is worn, torn or badly deteriorated. Is it rigid PVC or flexible pipe? If I prime the pump and turn it on it runs fine but when I turn it off and let it set for a few minutes you can hear it cheering then the water in the pump evacuates and there appears to be some water coming from the bottom of the pump. Could also be a loose high speed wire from the switch. the problem lies, where the power dies. Chapter 1: The Evil Emperor's Son. To keep the water clear, hand feed liquid or granular chlorine daily, and brush/skim the pool daily. Because all the pipes are new and no leaks have been evident, I can say with confidence that #2 is not it. Inspect for any damage to wires or wire casing. Hi if a 2-speed motor only works on low speed, that is usually a loose wire or hi/lo switch. Good news.not really. Good day everyone. Conversely, and by the way, when pressure is much lower than normal, that indicates an obstruction before the filter, like clogged pump or skimmer baskets or an impeller clog. By following the steps listed below, the Aqua Rite can successfully be restored.To view this guide step by step on our website, visit:http://www.inyopools.com/HowToPage/how_to_troubleshoot_a_hayward_aqua_rite.aspx Usually OK with a 12 lift, but more than that can be a struggle. Was working fine until I backwashed and cleaned the basket by the pump. Free, Pool Equipment Parts: Make your Own Repairs, https://www.intheswim.com/p/hayward-super-pump-pool-pump-motor-1-5-hp-threaded-shaft, https://www.intheswim.com/p/hayward-super-pump-shaft-seal-assembly-spx1600z2, http://waterheatertimer.org/How-to-wire-Hayward-two-speed-pump.html, https://hayward-pool-assets.com/assets/documents/pools/pdf/manuals/super-pump-vs-S2603VSP.pdf?fromCDN=true, https://www.intheswim.com/c/filter-parts?pcode=208&scode=SOCIBLOG, https://www.totallyhayward.com/techservices/attachments/Serial%20Number%20Read%20REVISED%201-2012.pdf, https://www.intheswim.com/images/PDFs/E1964-Manual.pdf, https://hayward-pool-assets.com/assets/documents/pools/pdf/manuals/tristar-vs-S3202VSP.pdf?fromCDN=true, https://www.intheswim.com/c/pump-parts?pcode=208&scode=SOCIBLOG, https://www.intheswim.com/p/hayward-spring-seal-w-seat-spx1250xz2c. Pump lids are often easier to remove when the Filter Air Bleeder is opened, to relieve vacuum pressure. Hello, I have a H200 natural gas heater . Tonight, I tried to manually start the filter and all I hear is a click in the mother board. Humming noise is usually associated with a bad capacitor, a black cylinder at 9 oclock in the rear of the motor. If the shaft spins freely, no rust problem. But after that, you should be able to override any programs with the buttons. "@type": "ImageObject",
It is a H400FDN series. Hi Mike, pumps are too hot to touch normally, running at 140 or so. How To Fix The Problem Diagrams, Pool If I push down on the the cover or apply weight to the top, the vibration reduces significantly. The pump starts up fine and draws water but then it starts clicking as if its shutting off and on. Ive been told my Hayward Vsp has been shutting itself off for low power issues, even though no power issues are present. switch in the center. Pool is ALMOST perfectly clear, BUT, for the life of me, I cannot get pressure to stay strong when vacuuming. Thanks, Put a meter on the terminal board, and see if the voltage coming into the motor is fluctuating or dropping off, when the motor cycles. Second thing is to see if the Motor Shaft Spins Freely, rust can develop which can bind up a motor. the , . Guess it is time for a new drive. No loose wires or insect infestation. When we first started both up there were no issues, however now when the heater kicks on the pump starts to make a high pitched noise. Jake, sounds like you got the filter up to speed. Hello my Hayward pump before it starts it buzzes for a few seconds and stops for a few seconds then repeats and after a couple of trays it starts running normal. Hi Liane, a click coming from a control panel, could be a relay, clicking to send the signal to start the pump, but the signal is lost along the way. Tripping the breaker, could possibly be a bad breaker, allowing too much voltage to pass thru to the pump. When I checked it again, the shaft (impellers) spin freely when tested by hand, but its not actually spinning when powered up? A warranty process with Hayward may take awhile, a few weeks this time of year I would think. pull the water through. If the impeller spins freely, does that mean the shaft is spinning freely or do I need to try to turn it from the back of the motor? A leaking shaft seal or drain plug could also drain the pump after some time. Motor will hum for a few seconds and eventually trip the breaker. The pump should really be on its own breaker if possible. What is happening? Hayward pumps use different shaft seals, you can find the correct one here: https://www.intheswim.com/c/pump-parts?pcode=208&scode=SOCIBLOG . An error was detected in the ignition control circuit board. Any new postings here are unlikely to be seen or responded to by other members. The temperature of the pool water is too high or too low to operate. Turn on the Drain King to pressurize all the way up to the pump, or to the filter valve, and whatever you see leaking water thats your air leak. The blower will run until error condition is corrected. Thank you. Any ideas? If the breaker is GFI, those are very sensitive, could be a bad breaker too. Air can also be drawn into the pump from leaky suction side valves (skimmer or main drain). Inspect the pipe/union connections on the suction side for loose connections or damaged pipes. Hello, I have a 2 yo, dual speed Hayward Super Pump (same as the one you have pictured above). About two weeks ago, my pool water level was very low and I believe this is were the air bubbles first presented. Hi, my pump has power and makes no noise. Also, using Teflon pool lube on the pump lid oring should help. This time around I purchased the t-3 cell model since my pool is below 15k gallons. You could also use a Hayward 24 sand filter, item E3324. The pipe connection became disconnected and flooded the pool house overnight after initial opening and start up Check that they are tight and havent come loose. (Yes, literally now.). The instant salinity in both polarities should be about the same (+/- about 200 ppm). If there is air in the basket it hums away loudly and sucks great to prime and fill the basket (the saltwater thing even appears to be working). The shaft turned with zero resistance. Initially, look into the pump/strainer housing. 3. pipe going into pump Thanks. Power can be checked at the motor terminals, with a multimeter set to AC volts. everything worked fine until we installed this pump. I dont know if Im convinced the new pump is bad or not, or if I need higher voltage to the pump. I calibrated the unit to 3100 ppm. We opened our pool today, ran the pump for about 7 or 8 hours and the plug on the pump was actually melted to the outlet on our timer. The arrow should point in the same direction as the water flow. Lube should not be the issue with the leak, not required. When I switch to waste or backwash, the suction is restored to full power and the flow is at full strength. If the clock motor is dead, you can replace just the motor, but most people replace the entire mechanism. My first thought is that the breaker may be too small for the amount of amps needed to start each piece of equipment. We are snow birds in AZ and want to drain the system for the summer. If so, put a damper under the pump, a piece of heavy rubber or a shim to stabilize the pump. I really dont know how long the motor was running like this when I discover the problem when I discover the problem the motor had already shut off. I will be purchasing a replacement pump and have it installed, but I wonder if Id need to just have the breakers tightened in the panel box? When incoming pipes or valves are clogged, you can get a surge. },
If you have a time clock or light switch in addition to the breaker, Id recommend using that to turn pump on/off, rather than the breaker. My pump motor does not start until I spin the shaft then it runs for about 15 min and shuts off and I can hear the motor humming and it feels very hot to the touch. http://www.inyopools.com/blogSHOP at our online store! Hi Davy, We hope these charts help solve your Hayward pool heater problems. BUT THE BEARINGS. bought a SP2610x152s super pool pump 1.5 hp. PUMP IS 15 YEARS OLD. Check for possible turbulence or obstructions inside of the flow T. Ensure there are at least 12 inches of straight pipe before the flow switch. The pump is working fine, however only the low speed is working. i have a hayward 240 super pump, which have had for about 10 years. I have a 2 speed motor and the high will not start at start up. Hi Ann, in such cases, I would probably use a plumbers Pipe Wrench or very large Channel Pliers may work, or I have seen custom tools home-made from 24 wood, that fit over the ridge on the lid, with a few inches on either side to push on, or tap with a hammer. Hi Ryan, it possibly could be a problem with running two extension cords, also could be voltage fluctuation, or loose terminal connections, or just a pump going bad. A closed valve, or plugs in the pool wall? Hello Davy, you just saved me a few hundred bucks. I have a Hayward Super II pump. Got a new motor, it made humming noise since day on,if i help it spin it works so I changed the capacitor and still the same, humming and if I help it to spin it goes fine, any suggestions? Is there a reset button or do I just need to wait until the water evaporates and it should turn back on? If I let it sit I can turn it on again, but just for about 20 seconds. With a flashlight (and your glasses), you can also look into the Visual Motor Check hole in the top of the mechanism, you should see gears moving. You can remove the wires and call your local Electric Motor Repair Shop, and see if they have this capacitor in stock, just read them the MFD number range printed on the side of the black cylinder. I have a perflex ec50 that is about four years old. I just purchased a new pump and installed it but once all the hoses are connected even with the pump off the pump is leaking from the strainer housing. Hayward North Star replaces capacitors Twice in a span of 3 month now pool pump not making any noise wondering if I can replace capacitor a third time. It is plugged into a gfi outlet. Poor connection inside the plug or socket. Inspect and clean your cell. so.it shut off again. I used the override switch and it fired up and left it on for several hours then turned it over to auto and it worked again but has since stopped. easier. There is another switch located at 6 oclock called the stationary switch. I have a Hayward Super Pump VS 2 hrs old. If you want, you can remove the capacitor and wrap it in a heavy cloth, or rubber sheet just in case. Then recharge with a good dose of DE powder. The filter is 3 4 years old. Do we need a new pump or can the electrical cord be replaced? Normally when the device is turned off and we do get the lid off, water runs back into the basket from the filter, it almost sounds like its creating almost a vapor lock, like in an engine. Pump Surging also occurs from low water level, or air leaks in front of the pump. Dear Davy, my pump was working two days ago then I switched it off. Grids not aligned properly, thus not pushed fully up into manifold Not sure whats wrong. He did notice that there was de inside of the filter grids so prior to putting it back together we completely flushed each of the grids making sure to get all the de out from inside of them. After 30 seconds it overheats and shuts down. My pump motor runs for 3-5 minutes ant then shuts off for about the same time. Step 3: Is your cell clean? The Aqua Rite runs at maximum out for for the remainder of the current pump cycle or for 24 hours, whichever comes first. Once we turn the pump on it runs good for a couple of mins then then once it builds up pressure the water pressure into the pool slowly stops. What should I do? Now, if your motor has cooled off, but wont start again, or make any noise at all, as you say i would check the power (volts) going into the motor, put the multimeter probes (set on 240V+) onto the two brass terminals of the motor terminal board, where the two incoming wires connect. The wiring is all new, new breakers and new sub box professionaly installed. I have a brand new Hayward super pump for my inground pool that my husband bought last year..this morning i turned it on and when i checked it about an hour later i noticed it was off and water around the switch and the plug and i also noticed there must have been a leak in the hose where the water can be drained from the pool so im guessi g the hose sprung a leak and wet everything..i checked the timer and the breaker and switched them off and on again and still no power..i saw a switch on the back of the pump and flipped it off then on again and still no power..im guessing it couldve got fried but im hoping im wrong..please help. Third, could be clogging in the filter, or bad filter sand, if you have a sand filter. You can experiment with pump RPM settings, to exceed the threshold. I have no display showing. I turned power off from breaker, emptied basket, used fingers to check for debris in impellers, did not find any. thanks. Also check that water level is good in pool, and skimmer weir is not blocking water flow. Hi Doug, good question that indicates that there is an air leak coming into the pump. dual-speed pool pump. If the wrong o-ring size was used, that could cause the problem. If it slowly rises your capacitor is capable of holding a charge. Hi Anmarie, Could be the wrong type of sand, but not likely if the bag said Pool Filter Sand on the label. Do I have a problem? UNK the , . And if you have Hayward heater error codes on display, that makes finding the problem almost easy! There should be no continuity. "@type": "Organization",
Fans of space opera and world-building fantasies will find this first book in the series compelling, concluding with a powerful vision of world-changing gods and attempts to free Eden from its curse that conclude in a cliffhanger for future books to explore. },
Is this a pump problem, priming problem (filter, pipes losing water somewhere)? The following steps will provide a guide on how to recalibrate a Hayward Aqua Rite. I am getting 24VAC from top Rectifier to PCB Input, says it should be 12VAC. What and how should I go about diagnosing this? Now what? Thanks! Stackable Rose Gold Wedding Bands, i just installed a vspnp hayward pump and when i flip the breaker on it only makes a clicking noise. The cell is new. All pipes are 1.5 and solidly installed with primer and high quality glue for the PVC used. Backwash several times to remove as much DE powder as possible, and then add 4 cups of DE powder for every 10 sq ft of filter surface area (see filter label if unsure). What can be the cause? more, View Can I replace a specific part or do I have to buy a new one? I connected Line 1&2 plus bond. When we turn on power, the pump does not make noise but the timer box and the circuit box make a light humming noise and then the circuit tripped. PDF | On Jan 1, 2009, Eduardo Keegan and others published Cognitive-behavior therapy. Hi Phil, hmmm, could be a breaker that is going bad they tend to wear out after 20 years or so, especially if they are used often, as a switch.